Press n or j to go to the next uncovered block, b, p or k for the previous block.
| 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 | 4x 19x 19x 19x 38x 14x 19x 13x 11x 11x 11x 11x 3x 7x 8x 4x 3x 7x 7x 6x 11x 11x 11x 11x 11x 7x 3x 3x 12x 16x 16x 5x 5x 11x 11x 1x 10x 16x 16x 4x 10x 16x 16x | import {
detectPhotometricFormat,
diagnoseIES,
parseIES,
parseLDT,
summarizeIES,
toPhotometricDocument,
validateIES,
LDTParseError,
IESParseError,
type IESDiagnostic,
type IESProfile,
type LDTProfile,
type PhotometricLampSet,
} from './index.js';
import { profileRanges, type SourceField } from './source.js';
import { unsupportedExtendedMetrics } from './metrics.js';
export type InputFormat = 'ies' | 'ldt';
export interface PhotometryDiagnostic extends Omit<IESDiagnostic, 'code'> {
code: string;
}
/** Explicit hint wins, then conventional extension; extensionless sources use content detection. */
export function inputFormat(text: string, file = '', hint?: InputFormat): InputFormat {
return hint ?? (/\.ies$/i.test(file) ? 'ies' : /\.ldt$/i.test(file) ? 'ldt' : detectPhotometricFormat(text));
}
export function ldtDiagnostics(profile: LDTProfile): PhotometryDiagnostic[] {
const diagnostics: PhotometryDiagnostic[] = [];
const ranges = profileRanges.get(profile);
// Usability advisories, not invented EULUMDAT required-keyword rules.
for (const field of ['identification', 'luminaireName'] as const) {
if (!profile[field].trim())
diagnostics.push({
code: 'LDT_MISSING_DESCRIPTION',
severity: 'warning',
field,
message: `The ${field} description is empty; adding it makes this file easier to identify`,
...(ranges?.[field] ? { range: ranges[field] } : {}),
});
}
return diagnostics;
}
export function validatePhotometry(
text: string,
format: InputFormat,
strict = false,
lampSetIndex?: number,
): { valid: boolean; profile: IESProfile | LDTProfile | null; diagnostics: PhotometryDiagnostic[] } {
if (format === 'ies') return validateIES(text, { strict });
try {
const profile = parseLDT(text);
const diagnostics = ldtDiagnostics(profile);
if (
lampSetIndex !== undefined &&
(!Number.isSafeInteger(lampSetIndex) || lampSetIndex < 0 || lampSetIndex >= profile.lampSets.length)
) {
diagnostics.push({
code: 'LDT_INVALID_LAMP_SET',
severity: 'error',
field: 'lampSetIndex',
message: 'The selected lamp configuration is outside the available lamp sets',
...lampSetRange(profile),
});
}
return {
valid: !diagnostics.some((item) => item.severity === 'error' || (strict && item.severity === 'warning')),
profile,
diagnostics,
};
} catch (error) {
if (!(error instanceof LDTParseError)) throw error;
return {
valid: false,
profile: null,
diagnostics: [parseErrorDiagnostic(error)],
};
}
}
function lampSetRange(profile: LDTProfile): Pick<PhotometryDiagnostic, 'range'> {
const range = profileRanges.get(profile)?.lampSetCount;
return range ? { range } : {};
}
function parseErrorDiagnostic(error: IESParseError | LDTParseError): PhotometryDiagnostic {
return {
code: error.code,
severity: 'error',
message: error.message,
...(error instanceof IESParseError && error.field ? { field: error.field } : {}),
range: error.range,
};
}
export interface PhotometrySourceDescription {
valid: boolean;
profile: IESProfile | LDTProfile | null;
diagnostics: PhotometryDiagnostic[];
/** Described source tokens and lines in document order. Partial when the text is invalid. */
fields: SourceField[];
}
/**
* Validate source text and describe every header line, keyword, angle and intensity it contains, for
* editor hover help and outlines. Never throws for malformed photometry: parse errors become diagnostics
* and `fields` covers the text read before the error. Diagnostics carry source ranges.
*/
export function describePhotometrySource(
text: string,
format: InputFormat,
strict = false,
): PhotometrySourceDescription {
const fields: SourceField[] = [];
try {
const profile = format === 'ies' ? parseIES(text, fields) : parseLDT(text, fields);
const diagnostics = format === 'ies' ? diagnoseIES(profile as IESProfile) : ldtDiagnostics(profile as LDTProfile);
return {
valid: !diagnostics.some((item) => item.severity === 'error' || (strict && item.severity === 'warning')),
profile,
diagnostics,
fields,
};
} catch (error) {
Iif (!(error instanceof IESParseError || error instanceof LDTParseError)) throw error;
return { valid: false, profile: null, diagnostics: [parseErrorDiagnostic(error)], fields };
}
}
type CoreSummary = ReturnType<typeof summarizeIES>;
export interface PhotometryInspection extends Omit<
CoreSummary,
'lampCount' | 'lumensPerLamp' | 'inputWatts' | 'peakCandela'
> {
sourceFormat: InputFormat;
lampCount: number | null;
lumensPerLamp: number | null;
inputWatts: number | null;
peakCandela: number | null;
selectedLampSetIndex: number | null;
lampSets: PhotometricLampSet[];
declaredLuminaireFluxLumens: number | null;
diagnostics: PhotometryDiagnostic[];
}
export function inspectPhotometry(text: string, format: InputFormat, lampSetIndex?: number): PhotometryInspection {
return inspectParsedPhotometry(format === 'ies' ? parseIES(text) : parseLDT(text), lampSetIndex);
}
function isLDTProfile(profile: IESProfile | LDTProfile): profile is LDTProfile {
return 'format' in profile && profile.format === 'ldt';
}
/** Inspect a validated native profile without parsing its source text again. */
export function inspectParsedPhotometry(profile: IESProfile | LDTProfile, lampSetIndex?: number): PhotometryInspection {
if (!isLDTProfile(profile)) {
const document = toPhotometricDocument(profile);
return {
...summarizeIES(profile),
sourceFormat: 'ies',
selectedLampSetIndex: null,
lampSets: document.lampSets,
declaredLuminaireFluxLumens: null,
diagnostics: diagnoseIES(profile),
};
}
const native = profile;
if (lampSetIndex !== undefined && lampSetIndex >= native.lampSets.length)
throw new RangeError('The selected lamp configuration is outside the available lamp sets');
const selected =
native.lampSets.length === 1 || lampSetIndex !== undefined
? toPhotometricDocument(native, { lampSetIndex })
: undefined;
const diagnostics = ldtDiagnostics(native);
if (!selected)
diagnostics.push({
code: 'LDT_LAMP_SET_SELECTION_REQUIRED',
severity: 'info',
field: 'lampSetIndex',
message:
'Lamp sets are alternative configurations; select a configuration to calculate intensity, flux and efficacy',
...lampSetRange(native),
});
const nativeLamp = selected ? native.lampSets[selected.selectedLampSetIndex ?? 0]! : undefined;
const summary = selected
? summarizeIES(selected.profile)
: {
format: 'EULUMDAT LDT',
version: 'EULUMDAT',
metadata: {
MANUFAC: native.identification,
TEST: native.reportNumber,
LUMINAIRE: native.luminaireName,
LUMCAT: native.luminaireNumber,
},
photometricType: 1,
photometricTypeName: 'C',
photometry: 'unselected',
lightSource: 'select a lamp configuration',
lampCatalog: 'not specified',
luminaire: native.luminaireName || 'not specified',
manufacturer: native.identification || 'not specified',
lampCount: null,
lumensPerLamp: null,
inputWatts: null,
peakCandela: null,
verticalAngles: native.gammaAngles.length,
horizontalAngles: native.cAngles.length,
units: 'meters' as const,
dimensions: {
width: native.luminousArea.width / 1000,
length: native.luminousArea.length / 1000,
height: Math.max(...native.luminousArea.heights) / 1000,
},
hasTilt: false,
fileGenerationType: null,
metricsSupported: false,
metricsUnsupportedReason: 'Select an alternative lamp configuration before calculating metrics',
declaredLampFluxLumens: null,
integratedFluxLumens: null,
luminousEfficacyLumensPerWatt: null,
beamAngles: [],
metricsTiltDegrees: 0,
...unsupportedExtendedMetrics,
};
return {
...summary,
format: 'EULUMDAT LDT',
sourceFormat: 'ldt',
selectedLampSetIndex: selected?.selectedLampSetIndex ?? null,
lampSets: native.lampSets,
declaredLuminaireFluxLumens: nativeLamp && nativeLamp.lampCount < 0 ? nativeLamp.totalLumens : null,
diagnostics,
};
}
|